2018 Good Quality Fatigue Design Of Offshore Steel Structures - Net Frame, Heterosexual Structure Class – Zhenyuan

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

We have been also specializing in improving the things administration and QC system to ensure that we could preserve terrific gain within the fiercely-competitive company for 4 Story Building Design, Home Structure Design, 2 Story Building Design, If you have the requirement for any of our products, please contact us now. We are looking forward to hearing from you soon.
2018 Good Quality Fatigue Design Of Offshore Steel Structures - Net Frame, Heterosexual Structure Class – Zhenyuan Detail:

Introduction

The basic units that make up the grid are triangular cone, triangular prism, cube, truncated quadrangle, etc. These basic units can be combined into trigons, quadrilateral, hexagons, circles or any other shape in a planar shape. It has the advantages of space stress, light weight, large rigidity, good seismic performance, etc. It can be used as the roof of gymnasium, cinema, exhibition hall, waiting hall, stadium stand awning, hangar, two-way large column grid structure and workshop.

Classification of grid:

The first type is composed of plane truss systems, which have four forms: two-way orthogonal spatial grid, two-way orthogonal sideways grid, two-way oblique sideways grid and three-way grid.

The second type is composed of quadrangular cone units, with five forms: normal quadrangular cone grid, normal evacuation quadrangular cone grid, oblique quadrangular cone grid, checkerboard quadrangular cone grid and star quadrangular cone grid.

The third category is composed of triangular cone units, with three forms: triangular cone grid, evacuated triangular cone grid and honeycomb triangular cone grid. Shell-type grid structures are mainly divided into cylindrical shell-type grid, spherical shell-type grid and hyperbolic paraboloid shell-type grid according to the form of shell surface. The grid structure is divided into steel grid, reinforced concrete grid and composite grid composed of steel and reinforced concrete according to the materials used, of which steel grid is widely used.

Internal force analysis of grid structure;

Grid structure is a high-order statically indeterminate structure system. In the analysis of plate grid, it is generally assumed that the joints are hinged, and the external load acts on the joints according to the principle of static equivalence, which can be calculated according to the space truss displacement method, i.e. the finite element method of hinged bar system. Simplified calculation methods, such as cross beam system difference analysis method and pseudo-plate method, can also be used to calculate internal forces and displacements. The joints of single-layer shell grid are generally assumed to be in rigid connections and shall be calculated according to the finite element method of rigid connections. The double-layer shell grid can be calculated by the finite element method of hinged bar system. The shell analogy method can also be used to simplify the calculation of single-layer and double-layer shell grids.

Design and structure of grid:

The bar section of the grid structure shall be calculated and determined according to the strength and stability. In order to reduce the calculated length of the compression bar and increase its stability, measures such as adding subdivided bars and supporting bars can be adopted. The joints of plate-type grid and double-layer shell-type grid made of steel mainly include cross plate joints, welded hollow spherical joints and bolted spherical joints. Cross plate joint is suitable for grid structure of section steel members. The connection between bars and joint plate is welded or high-strength bolted. Hollow spherical joints and bolted spherical joints are suitable for grid structures of steel pipe bars. The joints of single-layer shell grid structure shall be able to withstand bending internal forces. Under normal circumstances, the steel consumption of the joints accounts for about 15-20% of the steel consumption of the whole steel grid structure.

Net Frame, Heterosexual Structure Class

26

Plan of Web Bar of Grid

28

Grid Layout Plan

30

Grid Node Diagram

27

Plan of Lower Chord of Grid

29

Design Drawing of Three-Dimensional Joints of Grid


Product detail pictures:

2018 Good Quality Fatigue Design Of Offshore Steel Structures - Net Frame, Heterosexual Structure Class – Zhenyuan detail pictures


Related Product Guide:

We insist on offering high quality production with good business concept, honest sales and the best and fast service. it will bring you not only the high quality product and huge profit, but the most significant is to occupy the endless market for 2018 Good Quality Fatigue Design Of Offshore Steel Structures - Net Frame, Heterosexual Structure Class – Zhenyuan, The product will supply to all over the world, such as: Marseille, Lesotho, Korea, Customer's satisfaction is always our quest, creating value for customers is always our duty, a long term mutual-beneficial business relationship is what we are doing for. We are an absolutely reliable partner for yourself in China. Of course, other services, like consulting, can be offered too.
  • Good quality and fast delivery, it's very nice. Some products have a little bit problem, but the supplier replaced timely, overall, we are satisfied.
    5 Stars By Annabelle from Madrid - 2017.08.18 18:38
    Product variety is complete, good quality and inexpensive, the delivery is fast and transport is security, very good, we are happy to cooperate with a reputable company!
    5 Stars By Victor from Mexico - 2017.04.18 16:45